BPSXX - FIBER GLASS BUILDING INSULATION

  • MSDS: BPSXX
  • Manufacturer: MANVILLE SALES CORP
  • Product Name: FIBER GLASS BUILDING INSULATION
  • National Stock Number: 6540-00F025857
Product Identification

Product ID:FIBER GLASS BUILDING INSULATION
MSDS Date:07/30/1990
FSC:6540
NIIN:00F025857
MSDS Number: BPSXX

Responsible Party
MANVILLE SALES CORP
717 17TH ST
DENVER, CO 80127-5108
US

Emergency Phone: 303-978-2000

Info Phone: 303-978-4900

Preparer: RICHARD A. VERSEN

Cage: 75161

Contractor
MANVILLE SERVICE CORP
5108 DENVER, CO 80217 US

Telephone: 303-978-2902

Cage: 8V867

Ingredients

GLASS, OXIDE *92/3*

CAS: 65997-17-3

Fraction By Weight: 92-95%


UREA EXTENDED PHENOL FORMALDEHYDE RESIN CURED *92-3*

CAS: 25104-55-6

Fraction By Weight: 5-8%


FORMALDEHYDE, FORMALIN (2A CARCINOGEN BY NTP, IARC, OSHA)

CAS: 50-00-0

RTECS: LP8925000

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM; A2; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:INHALATION: IRRITATION OR SORENESS IN
THROAT & NOSE, CONGESTION. SKIN: IRRITATION OR RASH. INGESTION:
TEMPORARY IRRITATION TO GASTROINTESTINAL TRACT. EYES: TEMPORARY
IRRITATION OR INFLAMMATION.
Explanation of Carcinogenicity:SEE INGREDIENTS

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. DRINK WATER TO CLEAR THROAT
& BLOW NOSE TO EVACUATE FIBERS. SKIN: WASH GENTLY W/SOAP & WARM
WATER. EYES: FLUSH W/PLENTY OF WATER. OBTAIN MEDICAL ATTENTION IN
ALL CASES .

Fire Fighting

Extinguishing Media:CO2, WATER, WATER FOG, DRY CHEMICAL ABC RATED
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:RESIN & PAPER OR PLASTIC FACINGS WILL
BURN CAUSING DENSE ACRID SMOKE.

Accidental Release

Spill Release Procedures:PICK UP PIECES. VACUUM CLEAN DUSTS. IF
SWEEPING IS NECESSARY, USE DUST SUPPRESSANT (WATER).

Handling

Handling and Storage Precautions:KEEP MATERIAL DRY.

Exposure Controls

Respiratory Protection:<10 F/CC: USE NIOSH APPROVED DUST/MIST
RESPIRATOR, <50 F/CC: USE NIOSH FULL FACE RESPIRATOR W/H FILTER.
Ventilation:SUFFICIENT NATURAL OR MECHANICAL VENTILATION TO KEEP DUST
LEVEL BELOW PEL/TLV.
Protective Gloves:RECOMMENDED
Eye Protection:SAFETY GLASSES W/SIDESHIELDS
Other Protective Equipment:LOOSE FITTING, LONG SLEEVED CLOTHING
Work Hygienic Practices:WASH WORK CLOTHES SEPARATELY FROM OTHER
CLOTHING, RINSE WASHER THOROUGHLY.
Supplemental Safety and Health

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>1300F
Appearance and Odor:FIBROUS GLASS BLANKET, BATT, OR ROLL W/SLIGHT
PHENOLIC ODOR
Percent Volatiles by Volume:0%

Stability

Stability Indicator/Materials to Avoid:YES
HYDROFLUORIC ACID
Hazardous Decomposition Products:CO2, CO, CARBON PARTICLES & TRACES OF
HYDROGEN CYANIDE DERIVED FROM PYROLYSIS OF THE RESIN

Disposal

Waste Disposal Methods:WASTES ARE NOT HAZARDOUS AS DEFINED BY RCRA.
METHOD OF DISPOSAL: LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.